Boiler efficiency calculation: direct and indirect method with a worked example
Independent engineering sign-off is not claimed. Editorial standards & corrections
How to calculate boiler efficiency by the direct (input–output) and indirect (heat-loss) methods, with a worked steam boiler example, common mistakes and a free calculator.
Calculate, Understand & Investigate
In Calculators, choose “Boilers / steam generators”. Simple mode is free; Complex mode requires Professional access. Calculations support investigation, not equipment approval.
Choose "Boilers / steam generators": it calculates steam heat duty and the fuel needed at a stated efficiency. Compare its fuel figure with your metered fuel to check your boiler.
Two ways to calculate boiler efficiency
Boiler efficiency is the share of fuel energy that ends up in the steam. It can be found in two ways. The direct method, also called the input–output method, compares the heat added to the steam with the heat supplied in the fuel. The indirect method, also called the heat-loss method, adds up every measurable loss and subtracts the total from 100%.
Both methods are described in recognised test codes such as ASME PTC 4 and BS 845. Plants usually use the direct method for routine monitoring because it needs only flows, temperatures and the fuel heating value, and the indirect method when they want to know where the energy is being lost.
Direct method formula
Efficiency (%) = steam flow × (steam enthalpy − feedwater enthalpy) ÷ (fuel flow × fuel heating value) × 100.
Steam flow and fuel flow are in kg/h, enthalpies in kJ/kg and the heating value in kJ/kg. Take steam enthalpy from steam tables at the measured pressure and, for superheated steam, the measured temperature. Feedwater enthalpy is approximately 4.19 kJ/kg per °C of feedwater temperature at normal feed temperatures.
Worked example (illustrative values)
A boiler produces 10,000 kg/h of dry saturated steam at about 10 bar gauge. Steam tables give an enthalpy of about 2,781 kJ/kg. Feedwater enters at 80 °C, an enthalpy of about 335 kJ/kg. The boiler burns 700 kg/h of furnace oil with a gross calorific value of 42,000 kJ/kg.
Heat to steam = 10,000 × (2,781 − 335) = 24,460,000 kJ/h. Heat in fuel = 700 × 42,000 = 29,400,000 kJ/h. Efficiency = 24,460,000 ÷ 29,400,000 × 100 ≈ 83.2% on a gross calorific value basis.
These figures are for illustration only. Use your own measured flows, pressures, temperatures and laboratory fuel analysis.
Indirect (heat-loss) method
Efficiency (%) = 100 − the sum of all losses, each expressed as a percentage of fuel heat input. The indirect method needs a flue-gas analysis (oxygen or carbon dioxide and carbon monoxide), flue-gas and ambient temperatures, and the ultimate analysis of the fuel.
- Dry flue-gas loss — usually the largest; rises with stack temperature and excess air
- Loss from water formed by burning hydrogen in the fuel
- Loss from moisture in the fuel and in the combustion air
- Loss from incomplete combustion, shown by carbon monoxide in the flue gas
- Unburnt carbon in fly ash and bottom ash, mainly for solid fuels
- Radiation and convection loss from the boiler surfaces
Common mistakes that distort the result
- Mixing gross (GCV) and net (NCV) calorific values — always state which basis the efficiency uses; NCV-based figures are higher
- Using steam meter readings without pressure and temperature compensation
- Ignoring blowdown, which removes heated water that is not counted as steam
- Measuring over too short a period while load is changing
- Taking fuel flow from a level change without correcting for temperature and density
Improving efficiency after the calculation
Compare the result with the manufacturer's guaranteed value at the same load and fuel basis. If it is lower, the indirect method shows where to look: a high stack temperature points to fouled heat-transfer surfaces or a missing economiser; high oxygen points to excess air; carbon monoxide points to burner tuning. Record the efficiency monthly at a similar load so that trends become visible.
Industry 4.0 monitoring tip
Industry 4.0 boiler monitoring uses metered steam and fuel flow, feedwater temperature and flue-gas oxygen to calculate direct-method efficiency continuously. A falling daily efficiency at similar load is an early signal of fouling, poor combustion or excess blowdown.
Frequently asked questions
- What is the formula for boiler efficiency?
- Direct method: steam flow × (steam enthalpy − feedwater enthalpy) ÷ (fuel flow × fuel heating value) × 100. Indirect method: 100 minus the sum of all heat losses.
- Which is more accurate, the direct or indirect method?
- The indirect method is often preferred for acceptance testing because small measurement errors in losses have less effect on the result, and it shows where energy is lost. The direct method is simpler for routine monitoring.
- Should boiler efficiency use GCV or NCV?
- Either can be used, but the basis must be stated. Efficiency on a net calorific value basis is higher than on a gross basis for the same boiler.