Pump head calculation: total dynamic head formula with worked examples
Independent engineering sign-off is not claimed. Editorial standards & corrections
How to calculate pump total dynamic head (TDH) from static lift, pressure difference and pipe friction, with a worked metric example, a pressure-gauge method, an NPSH check and free calculators.
Calculate, Understand & Investigate
Use the Water Treatment guide for plant pumping context. In Calculators, choose “Mechanical”. Simple mode is free; Complex mode requires Professional access. Calculations support investigation, not equipment approval.
Choose "Pipe size & pressure drop". Simple mode finds the minimum pipe bore for a target velocity. Complex mode (Professional plan) adds Darcy–Weisbach friction, fitting losses, elevation and pump shaft power. For water, multiply its total pressure change in bar by about 10.2 to get metres of head.
Convert bar, kPa and psi to metres or millimetres of water (mH₂O) when comparing gauge readings with a pump data sheet.
What pump head means
Pump head is the energy a pump adds to each kilogram of liquid, expressed as the height of a column of that liquid, usually in metres. Expressing it as height is useful because a centrifugal pump produces the same head at a given flow and speed whatever the liquid density. The pressure it produces does change with density: the same 30 m of head is about 2.9 bar with water and about 2.5 bar with a light oil.
Total dynamic head (TDH) is the head the pump must deliver at the design flow to move liquid from the suction source to the destination. It is the number you match against the manufacturer's pump curve when you select or check a pump.
Total dynamic head formula
TDH = (z₂ − z₁) + (p₂ − p₁) ÷ (ρ × g) + (v₂² − v₁²) ÷ (2 × g) + hf
Point 1 is the liquid surface of the suction source and point 2 is the liquid surface or outlet at the destination. Heads are in metres, pressures in pascals, density ρ in kg/m³, g = 9.81 m/s² and velocity v in m/s.
- Static head (z₂ − z₁): the vertical rise from the suction liquid level to the discharge liquid level or outlet. A negative value means the destination is lower.
- Pressure head (p₂ − p₁) ÷ ρg: needed when the destination vessel is under pressure, for example a deaerator or a pressurised tank. It is zero when both ends are open to atmosphere.
- Velocity head (v₂² − v₁²) ÷ 2g: usually small. When liquid discharges into a tank, it is normally counted as an exit loss inside the fittings.
- Friction head hf: the loss in pipes, fittings, valves, strainers, heat exchangers and control valves at the design flow.
Calculating friction head with Darcy–Weisbach
hf = (f × L ÷ D + ΣK) × v² ÷ (2 × g), where f is the Darcy friction factor, L is the straight pipe length, D is the actual inside diameter and ΣK is the sum of fitting loss coefficients from a reliable table or the fitting manufacturer.
The friction factor depends on the Reynolds number (Re = ρ × v × D ÷ μ) and the pipe's relative roughness. For turbulent flow it is read from a Moody chart or calculated with the Colebrook or Haaland equation. Hazen–Williams is a simpler alternative that is valid only for water at normal temperatures. Equipment such as heat exchangers, filters and control valves should use the pressure drop on their data sheets at the design flow.
Worked example 1: cooling-water transfer pump (illustrative values)
Water at about 25 °C is pumped at 100 m³/h from an open sump to an open tank. The sump level is 2 m above the pump centreline and the tank level is 18 m above it, so the static head is 16 m. The line is 200 m of commercial steel pipe with a 150 mm inside diameter (roughness 0.045 mm) and fittings with a total K of 8, including the entry and exit losses.
- Flow: 100 ÷ 3,600 = 0.0278 m³/s. Pipe area: π × 0.15² ÷ 4 = 0.01767 m². Velocity: 0.0278 ÷ 0.01767 = 1.57 m/s.
- Reynolds number: 997 × 1.57 × 0.15 ÷ 0.00089 ≈ 264,000, so the flow is fully turbulent.
- Friction factor (Haaland): about 0.0170. Velocity head: 1.57² ÷ (2 × 9.81) = 0.126 m.
- Pipe friction: 0.0170 × 200 ÷ 0.15 × 0.126 ≈ 2.86 m. Fittings: 8 × 0.126 ≈ 1.01 m. Total friction head ≈ 3.86 m.
- Pressure head: 0, because both ends are open to atmosphere.
- TDH = 16 + 0 + 3.86 ≈ 19.9 m at 100 m³/h.
Pump power from head and flow
Hydraulic power (kW) = ρ × g × Q × H ÷ 1,000. In the example: 997 × 9.81 × 0.0278 × 19.9 ÷ 1,000 ≈ 5.4 kW. With an assumed pump efficiency of 75%, shaft power is about 7.2 kW. With an assumed motor efficiency of 93%, electrical input is about 7.7 kW.
Take the real pump and motor efficiencies from the manufacturer's curve at the duty point. Many designers add a margin to calculated friction for future fouling, but too much margin makes the pump run to the right of its best efficiency point or be throttled, which wastes energy.
Worked example 2: measuring head on a running pump
On site, head is found from suction and discharge pressure gauges. Head (m) = (p discharge − p suction) ÷ (ρ × g) + height difference between gauges + velocity head difference.
Illustrative readings: discharge gauge 3.8 bar g, suction gauge 0.3 bar g, discharge gauge 0.5 m higher than the suction gauge, and suction and discharge pipes of the same size. Head = (3.8 − 0.3) × 100,000 ÷ (997 × 9.81) + 0.5 ≈ 35.8 + 0.5 ≈ 36.3 m. Record the flow at the same moment and plot the point on the pump curve. Use calibrated gauges with suitable ranges; if the suction gauge reads vacuum, enter it as a negative pressure.
Check NPSH available on the suction side
A pump can have the right head and still cavitate. Net positive suction head available is NPSHa = (p surface − p vapour) ÷ (ρ × g) + z suction − hf suction, using absolute pressures.
Example with illustrative values: an open tank at 1.013 bar absolute, water at 30 °C (vapour pressure about 0.042 bar), liquid level 2 m above the pump and a suction line loss of 0.5 m. NPSHa ≈ (101,325 − 4,246) ÷ (995.6 × 9.81) + 2 − 0.5 ≈ 11.4 m. Compare it with the pump's NPSH required at the operating flow, plus the margin recommended by the manufacturer or guidance such as ANSI/HI 9.6.1. Hot liquids, such as boiler feed water, have a much higher vapour pressure and need careful checking.
Common mistakes in pump head calculations
- Measuring static head to the pump discharge flange instead of to the destination liquid level or outlet
- Using nominal pipe size instead of the actual inside diameter — friction varies roughly with the fifth power of diameter
- Forgetting the pressure in a closed destination vessel: 2 bar g is about 20.5 m of water head
- Leaving out strainers, heat exchangers or control valves, which often have larger losses than the pipe
- Converting pressure to head with the wrong density for hot water, brine or chemicals
- Adding large safety margins that push the pump far from its best efficiency point
Quick unit conversions
1 bar ≈ 10.2 m of water at about 20 °C. 1 m = 3.281 ft, so 19.9 m is about 65 ft. In US units, head (ft) ≈ psi × 2.31 ÷ specific gravity. Use the unit converter for other pressure and head units.
Industry 4.0 monitoring tip
With Industry 4.0 pump monitoring, suction and discharge pressure transmitters, a flowmeter and motor power are logged together. The system calculates the operating head and efficiency every few minutes and plots the duty point on the pump curve. A point that drifts away from the curve at the same speed is an early sign of impeller wear, a blocked strainer or a partly closed valve.
Frequently asked questions
- What is the formula for pump head?
- Total dynamic head = static head + pressure head + velocity head + friction head. Static head is the vertical rise, pressure head is (p₂ − p₁) ÷ ρg, and friction head is the loss in pipes and fittings at the design flow.
- How do I calculate pump head from pressure?
- Divide the pressure difference between discharge and suction by liquid density times gravity, then add the height difference between the gauges. For water, 1 bar is about 10.2 m of head.
- What is the difference between pump head and pressure?
- Head is energy per unit weight, expressed as a height of liquid, and is the same for any liquid at a given flow and speed. Pressure is head multiplied by density and gravity, so it changes with the liquid.
- Why does my pump not reach its rated head?
- Common reasons are a worn impeller, wrong rotation, air in the suction, cavitation from low NPSH available, a blocked strainer, or operating at a flow different from the rated point. Compare measured head and flow with the pump curve.