Utility Health Score
Pick one of 11 plant utilities, enter the readings you can measure, and get a weighted 0–100 score with the readings that pulled it down, suggested next checks and dated trends. Leave a field empty to skip a reading you cannot take.
Readings — Water Treatment Plant
Ideal bands are typical illustrations; verify with the OEM manual. Leave a field empty to skip it.
Ideal: 65–80 · Acceptable: 50–85 · Weight 3. Product flow divided by feed flow.
Ideal: 96–99 · Acceptable: 94–99.5 · Weight 4. Per-membrane or overall rejection per OEM test method.
Ideal: 10–16 · Acceptable: 8–20 · Weight 2. High-pressure pump discharge pressure.
Ideal: 1–3 · Acceptable: 0–5 · Weight 2. Stage-wise pressure drop; a rise signals fouling.
Ideal: 0–3 · Acceptable: 0–5 · Weight 5 · critical. Silt density index at the RO inlet; above 5 fouls membranes.
Ideal: 5–30 · Acceptable: 0–50 · Weight 5 · critical. Permeate conductivity; enter the design value to score against it.
Ideal: 0–5 · Acceptable: 0–10 · Weight 5 · critical. Hardness after the softener; regeneration may be due.
Ideal: 0.1–2 · Acceptable: 0–5 · Weight 3. Mixed-bed or DM outlet conductivity.
Ideal: 0–20 · Acceptable: 0–50 · Weight 3. Reactive silica at the DM outlet.
Ideal: 0.2–0.6 · Acceptable: 0–1 · Weight 2. Pressure drop across the multimedia filter.
Enter readings and calculate a score. Empty fields are skipped and noted in the result.
How the score works
Each parameter has an ideal band (green, 100 points) inside an acceptable band (amber, 50–99 points, scaled). Beyond the acceptable band the reading turns red (0–49 points). Parameters carry weights from 1 to 5, so a weighted average decides the overall score: Healthy 80+, Watch 60–79, At risk 40–59, Critical below 40. If any critical parameter — marked with an asterisk — turns red, the overall score is capped at 49 and the result shows “Critical attention needed”, because a critical reading such as a low fire-water tank or out-of-band boiler-water chemistry is more urgent than the average suggests.
Parameters marked “design” score against a design value you enter instead of the generic band — for example, your consent COD limit, your machine’s rated heat rate or your chiller’s design head pressure. Skipped readings are excluded and the result states how many parameters were used, so a score built on three readings is visibly weaker evidence than one built on ten.
The seeded bands are typical industry illustrations and each one is labelled “verify with the OEM manual”. The owner edits every band, weight and critical flag in the tool settings without code changes. Free accounts save 3 checks per day; Professional accounts save unlimited checks with full history, trend charts and PDF export. A green score never certifies equipment condition and never replaces OEM limits, permits or site procedures.
Guidance only. Follow manufacturer limits and site procedures; hazardous work requires qualified personnel.