Utilities Expert
Loading Utilities Expert
← Troubleshooter
Water Treatment · 8 min read

Reverse osmosis recovery calculation: formula, salt rejection and worked examples

Engineering content contact: Engr. Muhammad Aalam
Manager Utilities, Ismail Resin · Industrial utilities engineer
Content updated

Independent engineering sign-off is not claimed. Editorial standards & corrections

How to calculate RO recovery rate, salt rejection, salt passage, concentrate flow and concentrate TDS, with worked examples, what limits recovery and a free RO calculator.

Calculate, Understand & Investigate

In Calculators, choose “Water treatment (RO)”. Simple mode is free; Complex mode requires Professional access. Calculations support investigation, not equipment approval.

Photo, Video & Sound Analyzers →

Open the free RO recovery calculator →

Choose "Water treatment (RO)". It calculates permeate and concentrate flow and their TDS from feed flow, recovery and salt rejection. Complex mode (Professional plan) adds pump energy per m³ of permeate and a membrane-area screen.

Convert flow and concentration units →

Convert m³/h, L/min and US gpm, or mg/L and ppm, when your plant data and the membrane supplier's data use different units.

What RO recovery means

Recovery is the share of feed water that a reverse osmosis system turns into permeate (product water). The rest leaves as concentrate, also called reject or brine, carrying the salts the membranes have removed.

Recovery is constrained by feed chemistry, osmotic pressure, membrane flux, element/vessel recovery and minimum concentrate flow. Obtain a supplier-supported projection at actual temperature and composition; no generic brackish or seawater percentage establishes safe operation.

RO recovery and rejection formulas

  • Recovery (%) = permeate flow ÷ feed flow × 100
  • Concentrate flow = feed flow − permeate flow
  • Salt rejection (%) = (1 − permeate TDS ÷ feed TDS) × 100
  • Salt passage (%) = 100 − salt rejection = permeate TDS ÷ feed TDS × 100
  • Concentrate TDS = (feed flow × feed TDS − permeate flow × permeate TDS) ÷ concentrate flow — a salt mass balance
  • Concentration factor = concentrate TDS ÷ feed TDS, which is close to 1 ÷ (1 − recovery) when rejection is high

Worked example 1: brackish-water RO (illustrative values)

A plant receives 50 m³/h of feed water with 1,500 mg/L TDS. It produces 37.5 m³/h of permeate with 30 mg/L TDS.

  • Recovery = 37.5 ÷ 50 × 100 = 75%
  • Concentrate flow = 50 − 37.5 = 12.5 m³/h
  • Salt rejection = (1 − 30 ÷ 1,500) × 100 = 98%; salt passage = 2%
  • Concentrate TDS = (50 × 1,500 − 37.5 × 30) ÷ 12.5 = (75,000 − 1,125) ÷ 12.5 ≈ 5,910 mg/L
  • Concentration factor = 5,910 ÷ 1,500 ≈ 3.9, close to 1 ÷ (1 − 0.75) = 4

Worked example 2: what happens when recovery rises to 80%

Keep the same 37.5 m³/h of permeate but raise recovery to 80%. Feed flow becomes 37.5 ÷ 0.80 ≈ 46.9 m³/h and concentrate flow falls to about 9.4 m³/h. That saves about 3.1 m³/h of feed water, or roughly 75 m³ per day of continuous operation.

The assumed salt balance gives concentrate (46.875 × 1,500 − 37.5 × 30)/9.375 = 7,380 mg/L. This holds assumed product concentration constant for arithmetic only; it does not predict actual membrane response. Osmotic pressure requires composition and temperature, and a TDS-per-bar shortcut does not establish required feed pressure or scaling limits.

What limits RO recovery

The maximum safe recovery is usually set by the least soluble salt in the concentrate, not by the membrane itself. A water analysis and the membrane supplier's projection software, such as DuPont WAVE or Hydranautics IMSDesign, are used to confirm it.

  • Calcium carbonate scaling, judged with the Langelier (LSI) or Stiff & Davis index of the concentrate
  • Calcium sulphate, barium sulphate, strontium sulphate and calcium fluoride saturation
  • Silica concentration, which is strongly affected by temperature and pH
  • Antiscalant type and dose, which allow higher saturation but have their own limits
  • Osmotic pressure and the feed pump's pressure capacity
  • Membrane manufacturer limits on flux, per-element recovery and minimum concentrate flow per pressure vessel

Measuring recovery and rejection on site

Read permeate and concentrate flowmeters at the same time and check that their sum matches the feed meter; a large difference points to a meter error. If there is no feed meter, feed flow = permeate flow + concentrate flow.

Rejection is often estimated from conductivity because it is easy to measure online. Conductivity-to-TDS factors differ between feed, permeate and concentrate, so treat conductivity-based rejection as a trend value and confirm with laboratory TDS. Permeate flow and salt passage also change with temperature and pressure; normalise the data before comparing it with start-up values, as explained in our RO low permeate flow guide.

Common mistakes in RO recovery calculations

  • Increasing recovery by closing the concentrate valve without checking the scaling limits for the feed water
  • Using uncalibrated or unsynchronised flowmeters, which gives a wrong recovery
  • Confusing salt rejection (based on feed TDS) with the membrane's nominal rejection from the data sheet, which is measured under standard test conditions
  • Forgetting concentrate recycle: with recycle, the membrane feed is greater than the raw feed, so element-level and system recovery differ
  • Comparing permeate flow at different water temperatures without normalisation

Industry 4.0 monitoring tip

Time-aligned RO flow, conductivity, pressure and temperature trends support normalised performance investigation. An alert requires qualified assessment of supplier constraints, not an automatic instruction to close a concentrate valve or clean membranes.

Frequently asked questions

How do you calculate RO recovery?
Divide permeate flow by feed flow and multiply by 100. For example, 37.5 m³/h of permeate from 50 m³/h of feed is 75% recovery.
What is the difference between RO recovery and salt rejection?
Recovery is the share of feed water that becomes permeate. Salt rejection is the share of dissolved salt removed: (1 − permeate TDS ÷ feed TDS) × 100.
What is a good recovery rate for an RO plant?
Use feed-water analysis and the installed membrane supplier projection. Scaling, flux, element recovery and minimum concentrate flow constraints determine the permissible value, not a universal percentage.
How do I calculate RO concentrate TDS?
Use a salt mass balance: (feed flow × feed TDS − permeate flow × permeate TDS) ÷ concentrate flow. The free RO calculator on this site does this for you.

Technical References & Further Reading

Background sources, not endorsements or a claim of independent review. Use the applicable edition, installed manual and authorised site procedure for actual work.

This guidance is general. Always follow the equipment manufacturer's manual and your site safety procedures. See our engineering disclaimer.